Disconnect the 10P connector (A) from the driver's position memory switch (B).
Remove the two screws, then remove the switch from the door panel.
Check for continuity between the terminals in each switch position according to the table.
NOTE:
Make sure the correct test lead (+ or -) is placed on the terminal.
When checking for continuity across the diode, use the diode setting () on the digital volt/ohm meter to check the diode bias.
Note this important operating characteristic; diode bias causes a
diode to fully conduct electricity in one direction (forward), while
not at all in the opposite direction (reverse).
If the continuity is not as specified, replace the switch.
Honda Odyssey Owners Manual > Handling the Unexpected: Overheating
How to Handle Overheating Overheating symptoms are as follows: • The temperature gauge needle is at the mark or the engine suddenly loses power. • Steam or spray comes out of the engine compartment. ■ First thing to do 1. Immediately park the vehicle in a safe place. 2. Turn off all access ...