Honda Odyssey Service Manual: Alternator Brush Inspection

  1. Measure the length of both brushes (A) with a vernier caliper (B):

    • If either brush is shorter than the service limit, replace the brush holder assembly.

    • If the brush length is OK, go to step 14.

    Alternator Brush Length

    Standard (New):

    10.5 mm (0.413 in)

    Service Limit:

    1.5 mm (0.059 in)

  2. BA

    Exploded View

    Rotor Slip Ring Test

    See More:

    Honda Odyssey Service Manual > Hydraulic Power Steering Pump Overhaul: Inspection
    Check the flow control valve for wear, burrs, and other damage to the edges of the grooves in the valve. Inspect the bore of the flow control valve on the pump housing for scratches and wear. Slip the flow control valve back in the pump housing, and check that it moves in and out smoothly. If OK, g ...