Honda Odyssey Service Manual: A/C Refrigerant Recovery

Honda Odyssey Service Manual / HVAC / Cooling / A/C Refrigerant Recovery

caution
  • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.

  • Be careful when connecting service equipment.

  • Do not breathe refrigerant or vapor.

NOTE:

  • If accidental system discharge occurs, ventilate the work area before resuming service.

  • Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

  1. Connect an R-134a refrigerant recovery/recycling/charging station (A) to the high-pressure service port (B) and the low-pressure service port (C), as shown, following the equipment manufacturer's instructions.

  2. ACB
  3. Measure the amount of refrigerant oil removed from the A/C system after the recovery process is completed. Be sure to put the same amount of new refrigerant oil back into the A/C system before charging.

    Cooling

    A/C Service Tips and Precautions

    See More:

    Honda Odyssey Service Manual > HVAC: HVAC Sensors
    Rear Evaporator Temperature Sensor Replacement (With Climate Control) SRS components are located in this area. Review the SRS component locations   and the precautions and procedures   before doing repairs or service. Remove the rear HVAC unit. Disconnect the 2P connector (A) fro ...

    Honda Odyssey Owners Manual

    Honda Odyssey Service Manual