Honda Odyssey Service Manual: A/C Refrigerant Recovery

Honda Odyssey Service Manual / HVAC / Cooling / A/C Refrigerant Recovery

caution
  • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.

  • Be careful when connecting service equipment.

  • Do not breathe refrigerant or vapor.

NOTE:

  • If accidental system discharge occurs, ventilate the work area before resuming service.

  • Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

  1. Connect an R-134a refrigerant recovery/recycling/charging station (A) to the high-pressure service port (B) and the low-pressure service port (C), as shown, following the equipment manufacturer's instructions.

  2. ACB
  3. Measure the amount of refrigerant oil removed from the A/C system after the recovery process is completed. Be sure to put the same amount of new refrigerant oil back into the A/C system before charging.

    Cooling

    A/C Service Tips and Precautions

    See More:

    Honda Odyssey Owners Manual > Using Vents, Heating and A/C: Cooling
    1. Adjust the fan speed using the fan control dial. 2. Press the mode button to select . 3. Adjust the temperature using the temperature control dial. 4. Press the A/C button (indicator on). ■ To rapidly cool down the interior 1. Set the fan to the maximum speed. 2. Set the temperature to max ...

    Honda Odyssey Owners Manual

    Honda Odyssey Service Manual

    © 2018-2024 Copyright www.hodyssey.net
    0.0058