Honda Odyssey Service Manual: Alternator Brush Inspection

  1. Measure the length of both brushes (A) with a vernier caliper (B):

    • If either brush is shorter than the service limit, replace the brush holder assembly.

    • If the brush length is OK, go to step 14.

    Alternator Brush Length

    Standard (New):

    10.5 mm (0.413 in)

    Service Limit:

    1.5 mm (0.059 in)

  2. BA

    Exploded View

    Rotor Slip Ring Test

    See More:

    Honda Odyssey Owners Manual > Maintenance Under the Hood: Oil Check
    We recommend that you check the engine oil level every time you refuel. Park the vehicle on level ground. Wait approximately three minutes after turning the engine off before you check the oil. 1. Remove the dipstick (orange loop). 2. Wipe the dipstick with a clean cloth or paper towel. 3. Insert th ...